Complete instrumentation

Small Angle Neutron Scattering Spectrometer

  • Pre- and post-selector neutron guide with housing, support, vacuum system
  • Velocity selector with power supply, driving and safety
  • Neutron beam monitor with electronics
  • Collimator system with diaphragms, multi beam option, movable neutron guide elements, moving mechanism in evacuated telescopic tube, vacuum system
  • Sample table with variable sample environment (linear sample changer, goniometer, sample thermostat cooler-heater, He cryostat, sample electromagnet with power supply)
  • Movable XY-multidetector with signal processing electronics
  • Evacuated detector vessel with displacement mechanism, vacuum system, beam-stop mechanism
  • Secondary shutter and radiation shielding
  • Electronic control, driving and data acquisition system, computer configuration and software package specification
  • Wavelength range: 0.25 - 2.00 nm
  • Momentum (q) transfer range: 0.01 - 5.0 nm-1

Time-of-Flight Polarisation Neutron Reflectometer

Wavelength range: 0.25 - 1.25 nm
Momentum (q) transfer range: 0.05 - 3.0 nm-1
  • Secondary Beam Shutter with neutron guide
  • Tapered neutron guides QC = 3
  • Neutron beam monitor with electronics
  • Pre - and post Chopper Slit System
  • Variable resolution disk chopper system with radiation shielding
  • Supermirror analyser/polariser with RF flipper
  • Pre- and Post Sample Slit System
  • Sample table with variable sample environment, including:
    1. - goniometer
      - removable sample electromagnet up to 1.2 T
      - electromagnet power supply
      - sample changer for polarized / non - polarized samples
  • Detector vacuum vessel with positioning rail system
  • 2D position sensitive detector
  • Beam stop
  • Vacuum system
  • Electronic control, driving and data acquisition system

Residual Stress Neutron Diffractometer

  • Double focusing Si(311) bent perfect crystals monochromator with goniometric stage and rotating shielding
  • Take off angle range: 50°-120°
  • Gauge volume from 0.5x0.5x0.5 mm3 to 5x5x20 mm3
  • Secondary Beam Shutter
  • Neutron Beam Monitor with electronics
  • Slit system in the incident and diffracted beam
  • Oscillating radial collimator
  • Sample stage load up to 500 kg; XY-range: 300 mm ±0.05 mm; Z-range: 500 mm ±0.1 mm; whole 360° turn around Z; tilt angle along X axis: ±30° for 30 kg
  • 2D position sensitive detector with stage
  • Optic adjustment system
  • Air cushion movement system
  • Electronic control, driving and data acquisition system
  • Vacuum system

Triple Axis Spectrometer

  • Vertically focusing monochromator with goniometric stage and shileding
  • Diaphragm and Shutter (adjustable slit system)
  • Neutron Beam Monitor with electronics
  • Collimators with adjusting system and shielding
  • Sample stage load up to 400 kg; XY-range: 100 mm ±0.1 mm; whole 360° turn around Z; tilt angle along X axis: ±15°; size d500mm
  • Beam stop
  • Analyzer unit with goniometric stage and shileding
  • 2D position sensitive detector with stage

References »