Beam Shaping Devices

Diaphragm Changer

  • Positioning accuracy within ±5 µm
  • 10B / B4C / Al / Cd or sandwich absorbing plate
  • Absorption neutronically tested and certified
  • Variable size, variable apertures, custom designed
  • Remote controlled
  • Easy integration to existing systems

Double Slit Collimation System

  • Accuracy within ±10 µm
  • 10B / B4C / Al / Cd or sandwich absorbing blades
  • Absorption neutronically tested and certified
  • Variable size
  • Remote controlled
  • Easy integration to existing systems

Slit with laser targeting

  • Slit with remotely adjustable aperture. X,Y: 0.1-30 mm (customizable)
  • Compact, high-resolution industrial camera (5.0 MP)
  • Replaceable optics with adjustable focus
  • Red Laser Cross Line Module

Monochromator Device

Monochromator goniometric stage

  • Rotation around vertical axis
  • Double translate (±20 mm)
  • Double tilt (±15º)
  • High precision positioning accuracy
  • Remote controlled
  • Movement range customisation

Double focusing monochromator unit

  • Horizontal and vertical focusing
  • High-resolution positioning accuracy
  • Radiation hard components option
  • Variable length of crystals up to 300 mm
  • Installation and alignment of the
    Si crystal sandwich slabs
  • Bending mechanism with automatic wedge system
  • Remote controlled

Silicon single crystal production
for monochromator

  • Double focusing Si bent perfect crystal (BPC) monochromator
  • Silicon single crystal slabs asymmetric (311) with (511) option
  • Pecision cut for specified orientation
  • Orientation measured and certified by X-ray
  • Size and stack requirement as per request
  • High-precision parallelity by polishing

Multi-Beam Collimation Guide

  • Variable size, custom designed
  • B4C absorbing inner surfaces
  • Absorption neutronically tested and certified

Multi-Positioning Collimation System

  • Accuracy within ±10 µm
  • Four axis (X, Y, Z, tilting) positioning
  • 10B / B4C / Al / Cd or sandwich absorbing blades
  • Absorption neutronically tested
  • Operation under vacuum or in atmospheric pressure
  • Variable size and apertures

(Multi-)Sample Positioning System

  • Positional accuracy within ±10 µm
  • Heating/Cooling environment
  • Magnetic/Non-magnetic environment
  • Vacuum option

Collimator production

  • Soller Collimators
  • Radial Collimators
  • Radial Oscillating Collimators
  • Optimalization of absorbing element
  • Gd2O3 coated PET or textile glass
  • Collimator blades transmission are neutronically tested
  • Small angle scattering is reduced, certified
  • Controlled blade coating thickness: 10 – 100 micron
  • Both side of blade could be coated

Shutter production

  • Custom designed primary, secondary shutter
  • Pneumatic system / stepping motor
  • Vertical/horizontal rotating or linear moving
  • Optimalization of absorbing element
  • Electronic control system
  • Single or double beam shutter
  • Independent control option for double shutter
  • High-precision positioning accuracy
  • Customer specified neutron absorption

References »